LPR Коррозионный зонд

$1

The LPR Corrosion Probe is an accurate and reliable instrument. It measures real-time corrosion rates in water systems. Corrosion rate calculations are based on measurements of the current response to small polarizations (10 – 20mV) of the corrosion potential of the steel electrode.

Описание

The LPR Corrosion Probe is an accurate and reliable instrument. It measures real-time corrosion rates in water systems. Corrosion rate calculations are based on measurements of the current response to small polarizations (10 – 20mV) of the corrosion potential of the steel electrode. The immediate response also makes LPR probes suitable for the rapid detection of oxygen intrusion into systems that should not contain oxygen. Examples include water injection systems to maintain the integrity of pipelines and assets. Retractable LPR probes are available in hydraulic and mechanical access fitting systems.

Спецификация

Номинальное давление: стандартное 6000 фунтов на квадратный дюйм (420 бар) Опционально: 10 000 фунтов на квадратный дюйм (690 бар)
Maximum temperature: 145°C/293°F
Материал элемента зонда: углеродистая сталь St 52-3N в стандартной комплектации.
Материал основания зонда: Стандартные материалы: нержавеющая сталь и дуплексная сталь.
Разъем: 6-контактный амфеноловый (штекер)

Коррозионный зонд

Функции

1. (Проводящий) оператор при использовании в системах водоснабжения. У нас есть мгновенная информация о скорости коррозии.
2. Оператор может использовать опорный телескопический инструмент для обеспечения удобной установки и замены.
3. It is compatible with access fitting systems from most suppliers. So users install it in the mainstream 2” probe position.
4. Измерения зонда LPR легко понять и сопоставить.
5. Система онлайн-мониторинга коррозии использует профессиональную и надежную конструкцию датчиков и технологию производства. Это существенно повышает точность и чувствительность мониторинга коррозии. Система использует новую концепцию конструкции приборов. Это значительно улучшает стабильность системы и возможности обработки сигналов.

Обнаружение коррозии в трубопроводах:

Обнаружение коррозии трубопровода относится к обнаружению потери металла в трубопроводе с целью обнаружения коррозии стенок трубы. Этот подход обеспечивает понимание повреждений труб в процессе эксплуатации в рабочей среде. Обеспечение обнаружения дефектов и повреждений до того, как в трубопроводах возникнут серьезные проблемы, является фундаментальным решением проблемы. В прошлом традиционным методом обнаружения повреждений трубопровода был осмотр земляных работ или испытание трубопровода под давлением.

Этот метод является дорогостоящим и обычно требует установки стоп-лосса. Магнитный детектор коррозии утечки и ультразвуковой детектор обычно используются при проверке трубопровода. Он может определять размер и расположение коррозионных язв, коррозионных трещин под напряжением, усталостных трещин и других повреждений.

Помимо высокой точности и надежности, интеллектуальный детектор высокого разрешения также может различать дефекты внутри и снаружи стенки трубы. На основе анализа и оценки данных обнаружения коррозии менеджеры могут разработать экономичные и разумные планы технического обслуживания. Это экономит затраты на техническое обслуживание и может определить будущие безопасные условия эксплуатации и оставшийся срок службы трубопровода. Это обеспечивает длительную безопасную и экономичную эксплуатацию трубопровода.

Коррозионный зонд

Необходимость в системе обнаружения коррозии

Corrosion problems exist in almost all walks of life. The oil refining industry operates under high temperatures and pressure. The medium is poisonous and harmful, flammable and explosive. Corrosion is therefore particularly serious in the oil refining industry. Corrosion monitoring and detection is the foundation and basis of the entire anti-corrosion work. It is the first link in the “supervision, management, and control” system of anti-corrosion work. Therefore, strengthening the corrosion monitoring and testing of equipment is of great significance to anti-corrosion work, and it is urgent.

1. Несколько распространенных датчиков коррозии

Электрохимические датчики, датчики сопротивления и датчики индуктивности в настоящее время широко используются для онлайн-мониторинга коррозии.

1.1 Электрохимические датчики рассматривают коррозию как функцию батареи.

Таким образом, скорость коррозии пропорциональна току коррозии. Мы можем рассчитать скорость коррозии по току коррозии.

1.2 Принцип измерения резистивного зонда:

В агрессивных средах провода, используемые в качестве измерительных элементов, подвергаются коррозии. При этом длина металлической проволоки остается неизменной, диаметр уменьшается, а сопротивление увеличивается. Мы можем устранить коррозию и истончение проволоки, проверив изменение сопротивления. Это, в свою очередь, отражает степень коррозии по толщине стенки.

1.3 Принцип действия индуктивного датчика:

Коррозия и замена зонда напрямую влияют на индуктивность, что, в свою очередь, приводит к снижению коррозии.

Они подходят для различных температур, давлений и условий эксплуатации. Некоторые зонды также имеют разную степень слабости. Поэтому в процессе использования необходимо разумное использование, чтобы добиться точных и своевременных результатов.

2. Разъемная установка зонда под давлением.

В реальных условиях зонд часто устанавливают разъемным способом под давлением. Этот метод установки позволяет разобрать и заменить датчик без обхода и без отключения. Однако этот метод чаще всего используется в криогенном оборудовании и трубопроводах. В настоящее время производитель обычно выбирает маслостойкие уплотнительные материалы для прокладок. Его материал – маслостойкая резиновая асбестовая плита. Поверхность уплотнения фланца выбирает выступающую поверхность уплотнения.

3. Не может быть установлен с напорным фланцем.

Для установки фланцевого датчика LPR без давления требуется, чтобы диаметр испытываемого трубопровода был не менее 150 мм. Длина зонда, заходящего вглубь трубопровода, не менее 100 мм. Длина короткого замыкания не должна быть менее 210 мм. Чтобы обеспечить стабильность зонда, производитель часто добавляет кольцевое уплотнительное кольцо на выходе короткого соединения, которое играет фиксированную роль.

4. Резюме

Независимо от того, разъемная ли это установка под давлением или фланцевая установка без давления. Как правило, рекомендуется устанавливать в байпасном, боковом или других переключаемых положениях при высоких температурах. Это может снизить вероятность несчастных случаев и повысить коэффициент безопасности. Выбор, материал, модель и показатели экологических параметров коротких соединений, фланцев и арматуры в процессе монтажа должны соответствовать нормам проектирования трубопроводов.

Отзывы

Пока нет отзывов.

Be the first to review “LPR Коррозионный зонд

Ваш электронный адрес не будет опубликован. Обязательные поля помечены *

3 × four =

Шэньянская компания EMT Piping Technology Co., Ltd.

Связаться

Рабочее время

  • Будни 8:00 - 20:00
  • Суббота 9:00 - 16:00
  • Воскресенье Закрыто
  • Каникулы 10:00 - 14:00

Язык